[ Next-in-Thread ]  [ Next Message ] 

Question: RH6.1 on Toshiba 2100CDS does network start twice? 

Forum: 3Com PCMCIA Ethernet Adapter Issues
Date: 2000, May 15
From: Tony Curtis tonyc

When the 3c575_cb card is inserted cardmgr runs "/etc/pcmcia/network start" twice. This then starts 2 "pump -i eth0" processes and I guess that one eventually wins because eth0 comes up with address and the ifup-post and ifup-local scripts do the right thing, but it takes up to 30 seconds. Doing all the bits by hand succeeds immediately.

I can't work out why the network script runs twice.

RH6.1 with 2.2.14 kernel. pcmcia-utils 3.1.13

dmesg has this to say about the 3com card:

 --
 eth0: 3Com 3CCFE575CT Cyclone CardBus at 0x200,   
   00:50:04:e9:03:14, IRQ 5
 eth0: CardBus functions mapped 60020000->c205c000
  8K byte-wide RAM 5:3 Rx:Tx split, MII interface.
  MII transceiver found at address 0, status 7809.
  Enabling bus-master transmits and whole-frame receives.
 --

I simplified /etc/pcmcia/network to just run "ifup eth0" but I get the same problems, so I suspect the problem is not there. Is cardmgr launching network twice?

thanks tony

[ Next-in-Thread ]  [ Next Message ] 

Messages Inline: [ 1 ]  [ All ]  Outline: [ 1 ]  [ 2 ]  [ All ] 

1. Without system log messages, I can't tell by David Hinds, 2000, May 15
(_ More: Fudgy fix for doubled "network start" by Tony Curtis, 2000, May 16
(_ Maybe you can fiddle with delays by David Hinds, 2000, May 16
(_ More: using delays to get the pump process working by Tony Curtis, 2000, May 16

[ Add Message ]  to: "RH6.1 on Toshiba 2100CDS does network start twice?"

[ Members ]  [ Subscribe ]  [ Admin Mode ] 
[ Show Frames ]  [ Help for HyperNews at pcmcia-cs.sourceforge.net 1.10 ]