Next-in-Thread Next Message

Question Possible erroneous manfid in config file? 

Forum: PCMCIA Network Adapter Issues
Date: 1999, Dec 13
From: Brian Mays brian

The Corega PCC-T Ehternet PCMCIA card (NE2000 clone) identifies its manfid as 0xc00f, 0x0000.

 $ cardctl ident 0
   product info: "corega K.K.", "corega Ether PCC-T"
   manfid: 0xc00f, 0x0000
   function: 6 (network)

But in pcmcia-cs 3.1.5, the config file config has another entry which also has manfid as 0xc00f, 0x0000.

 card "Allied Telesyn AT-2800 10/100 Fast Ethernet"
   manfid 0xc00f, 0x0000
   bind "tulip_cb"

Therefore, when a PCC-T Ethernet card is used, pcmcia-cs tried to install tulip_cb modules (instead of pcnet_cs), which results in errors.

Is the manfid for the AT-2800 correct or is something else wrong?

Next-in-Thread Next Message

Messages Inline: 0 1

None Well, one of them is wrong...

Re: Question Possible erroneous manfid in config file? (Brian Mays)
Date: 2000, Jan 14
From: David Hinds <dhinds@pcmcia.sourceforge.org>

I'll comment out the Allied Telesyn entry in future PCMCIA releases,
until it is sorted out.  We'll need to get product info strings for
the Allied Telesyn card.

-- Dave