|
Hi Dave, I got and installed the Jul 27 beta package but the results are the same (same values in dmesg and /va/log/messages). I have some new info also. I downloaded and installed the epic-diag.c from Scyld and run the following: localhost.localdomain:/root/tecra>epic-diag -a epic-diag.c:v2.00 4/19/2000 Donald Becker (becker@scyld.com) http://www.scyld.com/diag/index.html Index #1: Found a SMSC EPIC/C 83c175 adapter at 0x1100. The EPIC/100 chip appears to be active, so some registers will not be read. To see all register values use the '-f' flag. No interrupt sources are pending. Rx state is 'Running', Tx state is 'Idle'. Transmitter: slot time 512 bits, half-duplex mode. Last transmit FAILED!!, 0 collisions. Receiver control is 000c, multicast mode. The last Rx frame was 0 bytes, status 0. Index #2: Found a SMSC EPIC/C 83c175 adapter at 0x1000. The EPIC/100 chip appears to be active, so some registers will not be read. To see all register values use the '-f' flag. Interrupt sources are pending. Rx Buffer Overflow indication. Rx threshold crossed indication. Rx state is 'Running', Tx state is 'Running'. Transmitter: slot time 320 bits, full-duplex mode. Last transmit FAILED!!, 8 collisions. Receiver control is 4f4f4f4f, monitor only mode. The last Rx frame was 1330597711 bytes, status 8080808, Missed/Overflow. localhost.localdomain:/root/tecra>epic-diag -e epic-diag.c:v2.00 4/19/2000 Donald Becker (becker@scyld.com) http://www.scyld.com/diag/index.html Index #1: Found a SMSC EPIC/C 83c175 adapter at 0x1100. The EPIC/100 chip appears to be active, so some registers will not be read. To see all register values use the '-f' flag. No interrupt sources are pending. Rx state is 'Running', Tx state is 'Idle'. Transmitter: slot time 512 bits, half-duplex mode. Last transmit FAILED!!, 0 collisions. Receiver control is 707000c, multicast mode. The last Rx frame was 0 bytes, status 0. Parsing the EEPROM of a EPIC/100: Station Address 00:00:00:00:00:00. Board name '', revision 0. Calculated checksum is 00, correct. Subsystem ID Vendor/Device 0000/0000. Index #2: Found a SMSC EPIC/C 83c175 adapter at 0x1000. The EPIC/100 chip appears to be active, so some registers will not be read. To see all register values use the '-f' flag. Interrupt sources are pending. Rx Buffer Overflow indication. Rx threshold crossed indication. Rx state is 'Running', Tx state is 'Running'. Transmitter: slot time 320 bits, full-duplex mode. Last transmit FAILED!!, 8 collisions. Receiver control is 4f4f4f4f, monitor only mode. The last Rx frame was 1330597711 bytes, status 8080808, Missed/Overflow. Parsing the EEPROM of a EPIC/100: Station Address 00:00:00:00:00:00. Board name '', revision 0. Calculated checksum is 00, correct. Subsystem ID Vendor/Device 0000/0000 localhost.localdomain:/root/tecra>epic-diag -m epic-diag.c:v2.00 4/19/2000 Donald Becker (becker@scyld.com) http://www.scyld.com/diag/index.html Index #1: Found a SMSC EPIC/C 83c175 adapter at 0x1100. The EPIC/100 chip appears to be active, so some registers will not be read. To see all register values use the '-f' flag. No interrupt sources are pending. Rx state is 'Running', Tx state is 'Idle'. Transmitter: slot time 512 bits, half-duplex mode. Last transmit FAILED!!, 0 collisions. Receiver control is 000c, multicast mode. The last Rx frame was 0 bytes, status 0. MII PHY found at address 1. MII PHY #1 transceiver registers: 3100 7809 0300 e54a 01e1 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0140 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000. Index #2: Found a SMSC EPIC/C 83c175 adapter at 0x1000. The EPIC/100 chip appears to be active, so some registers will not be read. To see all register values use the '-f' flag. Interrupt sources are pending. Rx Buffer Overflow indication. Rx threshold crossed indication. Rx state is 'Running', Tx state is 'Running'. Transmitter: slot time 320 bits, full-duplex mode. Last transmit FAILED!!, 8 collisions. Receiver control is 4f4f4f4f, monitor only mode. The last Rx frame was 1330597711 bytes, status 8080808, Missed/Overflow. ***WARNING***: No MII transceivers found! But, when I executed the last command (epic-diag -m) the green light on my switch went ON. Still not able to do any route add or ping. Do you think that more info (to add in /etc/conf.modules "option epic_cb debug=6 full_dupplex=1") might help? Thanks for cooperation, Cristian |
Messages
Sorry, my mistake...
| |
| |
|